Place of Origin: | England |
Brand Name: | MTL |
Certification: | CE |
Model Number: | MTL5544D |
Minimum Order Quantity: | 10 pcs |
---|---|
Delivery Time: | in stock |
Payment Terms: | T/T |
Supply Ability: | 500 pcs |
MTL5500 replacement in existing installations
The MTL5500 is designed with the same 16mm case width and similar profile to the MTL5000 series. This permits the replacement of an MTL5000 module with the new equivalent in the MTL5500 range. In most instances the cable connection to the field terminals are identical so the module can simply be replaced and the terminals reconnected in a matter of seconds. The power supply plugs are also compatible on both ranges.
MTL5000 | Function | MTL5500 | Notes |
MTL5011B | 1ch, changeover relay output | MTL5511 | |
MTL5012 | 1ch, solid-state output | Use 1ch of MTL5513 | |
MTL5012S | 1ch, solid-state output, UE1 special | No replacement | |
MTL5014 | 1ch, c/o relay output, LFD relay | MTL5514/14D |
MTL5514 does not provide 1in 2out function. MTL5514D with 1in 2out available Q1 2014 |
MTL5015 | 2ch, solid-state output | MTL5513 |
Common connection on haz side, max frequency response 500Hz |
MTL5016 | 2ch, n/o relay output | MTL5516C | |
MTL5017 | 2ch, n/o relay output, LFD relay | MTL5517 | LFD relay energises on alarm |
MTL5018 | 2ch, changeover relay output | MTL5516C | Common connection on haz side |
MTL5018ac | 2ch, changeover relay output, ac power |
Continues as MTL5018ac. Alternative option: MTL5516C fitted with MPA5500 ac adaptor |
|
MTL5021 | Loop powered, IIC, (12.85V, 45mA, cl 45mA) | MTL5521 | (12.8V, 48mA, cl 48mA) |
MTL5022 | Loop powered, IIB, (12.9V, 60mA, cl 60mA) | MTL5522 | (9.9V, 70mA, cl 70mA) |
MTL5023 | Logic ctrl, lfd, phase,(12.85V, 45mA, cl 45mA) | MTL5523 | (12.8V, 48mA, cl 48mA) |
MTL5024 | Logic ctrl, phase, (12.85V, 45mA, cl 45mA) | MTL5524 | (12.8V, 48mA, cl 48mA) |
MTL5025 | Loop powered, IIC, (8.6V, 45mA, cl 45mA) | MTL5525 | (7V, 48mA, cl 48mA), lower Io |
MTL5031 | Vibration transducer interface | MTL5531 | Now Velomitor compatible |
MTL5032 | Pulse isolator | MTL5532 | Now with 4-20mA output and alarm |
MTL5040 | Loop isolator | Use MTL5541 and MTL5546Y | |
MTL5041 | For 2-wire transmitters | MTL5541 | |
MTL5042 | For 2- or 3-wire txs, smart | MTL5541 | |
MTL5043 | Dual output for 2-wire smart txs | MTL5544D | No current sink o/p. Passive Tx input |
MTL5044 | Two channel for 2-wire txs | MTL5544 | Now with passive Tx inputs |
MTL5045 | Isolating driver | MTL5546Y | Smart only versions |
MTL5046 | Smart isolating driver with LFD | MTL5546 | |
MTL5049 | Two channel isolating driver | MTL5549Y | Smart only versions |
MTL5051 | Serial-data comms isolator | Continues as MTL5051 model | |
MTL5053 | Fieldbus isolator/power supply | Discontinued | |
MTL5061 | Fire/smoke detector interface | MTL5561 | |
MTL5073 | Temperature converter | MTL5575 | Now with trip alarm |
MTL5074 | Temperature converter | MTL5575 | Now with trip alarm |
MTL5081 | mV/THC isolator | MTL5581 | |
MTL5082 | Resistance isolator | MTL5582 | |
MTL5113P | Failsafe sw/prox interface | MTL5501-SR | |
MTL5314 | Trip amplifier | Continues as MTL5314 model | |
MTL5344 | Repeater power supply | Discontinued | |
MTL5349 | Isolating driver | Discontinued | |
MTL5991 | 24V power supply | Continues as MTL5991 model | |
MTL5995 | Fieldbus power supply | Convert to F10X range product |